The Frymaster FPPH255 is a high-performance gas fryer designed for commercial kitchen use, featuring a 25-pound fat capacity, solid-state temperature controls, automatic basket lifts, high-efficiency burners, stainless steel construction, built-in filtration system, cool zone for sediment collection, digital temperature display, and safety features including high-limit thermostat and flame failure protection. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Stainless steel fry pot, solid-state temperature controller, automatic basket lift mechanism, high-efficiency gas burner, built-in filtration system, digital temperature display, drain valve, and cool zone.
| Feature | Description |
|---|---|
| Fry Pot Capacity | 25 lbs fat capacity |
| Heating System | High-efficiency gas burner with flame failure protection |
| Temperature Control | Solid-state digital controller with ±5°F accuracy |
| Basket Lift | Automatic electric lift system |
| Filtration System | Built-in pump filter with manual or automatic modes |
| Construction | 304 stainless steel exterior and fry pot |
| Display | Digital LED temperature readout |
| Safety Features | High-limit thermostat, flame failure device, over-temperature protection |
| Drain Valve | Manual lever-type drain for easy oil removal |
| Cool Zone | Bottom area for sediment collection to extend oil life |
Unpack and inspect for shipping damage. Position on level, stable surface.
WARNING! Installation must be performed by qualified technician. Ensure proper gas pressure and leak test all connections.
Before initial use, complete seasoning and temperature calibration.
CAUTION! Never operate without oil/fat in fry pot. Allow unit to cool completely before servicing.
Control Panel: POWER switch, Temperature control knob, Basket Lift buttons (UP/DOWN), Filter button, Digital display.
Temperature Control: Solid-state controller with digital setpoint adjustment. Press SET button, use arrows to adjust temperature, press ENTER to confirm.
Basket Lift: UP button raises basket, DOWN lowers. Automatic timer available (set in menu).
Filter System: FILTER button activates pump. Can be set to manual or automatic mode.
Menu Settings: Hold SET for 3 seconds to access: Temperature calibration, Basket timer (0-5 min), Filter timer, Temperature units (°F/°C), High-limit setting.
Gas: 3/4" NPT gas connection. Electrical: 3-prong grounded plug. Ventilation: Must connect to exhaust hood.
Tip: Verify gas type matches unit configuration (natural gas or propane).
Daily operation for optimal performance and safety.
WARNING! Never add water or ice to hot oil. Keep floor area clean and dry.
Built-in filtration extends oil life and improves food quality.
Frequency: Filter daily for heavy use, every 2-3 days for moderate use.
Regular maintenance ensures safety and extends equipment life.
Daily: Wipe exterior with damp cloth. Clean basket and fry area. Check drain valve for leaks.
Weekly: Remove and clean baskets in degreaser. Clean inside of fry pot (when cool). Check burner for proper flame pattern.
Monthly: Inspect gas connections. Clean pilot assembly. Check safety valve operation.
Annually: Professional inspection of all safety devices, thermostat calibration, burner adjustment.
CAUTION! Always disconnect power and gas before cleaning. Never use water spray on electrical components.
NSF/UL certified for commercial use. Complies with ANSI Z83.11 for gas-fired fryers. CSA certified for Canada. Manufactured to meet FDA food equipment standards. For support, contact Frymaster Technical Service at 1-800-221-4583 or visit www.frymaster.com. Serial number located on rating plate inside door.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition | Gas supply, pilot, electrical | Check gas valve open; verify pilot flame; check power connection. |
| Temperature fluctuates | Thermostat, sensor, oil level | Calibrate thermostat; check sensor connection; maintain proper oil level. |
| Basket lift not working | Motor, switch, obstruction | Check power to motor; test lift switch; remove any obstructions. |
| Oil not heating | Burner, thermostat, gas pressure | Clean burner ports; test thermostat; verify gas pressure (7" WC natural gas). |
| Filter pump not working | Motor, clog, electrical | Check pump motor; clean filter lines; verify electrical connection. |
| Oil smoking excessively | Oil degradation, temperature | Change oil; verify thermostat accuracy; clean cool zone. |
Reset: Turn POWER off for 30 seconds to reset electronic controls.
Service: 1-800-221-4583; www.frymaster.com