The Frymaster RE17-2BLC-SD is a high-efficiency, 17-inch gas fryer with solid-state controls, built-in filtration system, dual baskets, automatic basket lifts, and a stainless steel construction. It features a 65 lb. shortening capacity, 120,000 BTU input, digital temperature control, melt cycle, and built-in safety systems including high-limit thermostat and flame failure device. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Stainless steel fry tank with dual baskets, Solid-State Control Board, Filtration System, Automatic Basket Lifts, Digital Temperature Controller, Gas Burner Assembly, Drain Valve.
| Feature | Description |
|---|---|
| Solid-State Controls | Microprocessor-based for precise temperature and timing |
| Built-in Filtration System | Pump and filter for daily shortening maintenance |
| Automatic Basket Lifts | Motorized lift system for consistent frying |
| Digital Temperature Control | LED display with ±5°F accuracy |
| Melt Cycle | Automatically melts solid shortening |
| High-Limit Thermostat | Safety cut-off to prevent overheating |
| Flame Failure Device | Shuts off gas if flame is lost |
| Dual Baskets | Two 14" x 9" baskets for high-volume frying |
| Drain Valve | Stainless steel valve for easy shortening drainage |
| POWER Switch | Main electrical power ON/OFF |
Unpack and inspect contents. Place on level, stable surface capable of supporting 800 lbs.
WARNING! Installation must be performed by qualified personnel. Ensure adequate clearance from combustible materials.
Power on fryer; follow initial startup procedure.
CAUTION! Never use water to extinguish a grease fire. Have a Class K fire extinguisher readily available.
Access functions via front control panel. Main Controls: POWER, TEMP UP/DOWN, MELT, LIFT, FILTER, RESET.
Control Panel: Digital Temperature Display, Power Indicator Light, High-Temp Warning Light, Basket Lift Buttons (Left/Right), Filter Start Button.
Temperature: Set cooking temp with UP/DOWN arrows. Melt Cycle: Initiates automatic solid shortening melt. Basket Lifts: LOWER/RAISE buttons for each basket. Filter System: Activates pump and filter circuit. Reset Button: Resets control board after high-limit trip or fault.
Gas: 3/4" connection with manual shut-off valve. Electrical: 120V grounded outlet. Ventilation: Exhaust hood.
Tip: A licensed gas fitter and electrician must perform connections to meet local codes.
For frying various food products.
WARNING! Never mix water with hot oil. Stand clear when lowering baskets to avoid splatter.
Daily filtration extends shortening life. Weekly cleaning maintains performance.
Daily Filtration: 1. Heat oil to 250°F. 2. Press FILTER. 3. Open drain valve, allow oil to pump into filter tank. 4. Clean fry tank interior. 5. Close drain valve, press FILTER to return oil.
Weekly Cleaning: 1. Cool unit completely. 2. Drain all oil. 3. Remove baskets and scrub tank with fryer cleaner and nylon brush. 4. Rinse thoroughly and dry. 5. Refill with fresh shortening.
CAUTION! Always cool oil before draining. Wear protective gloves and eyewear.
| Frequency | Task |
|---|---|
| Daily | Filter shortening, wipe exterior, check for leaks |
| Weekly | Thoroughly clean fry tank, inspect baskets |
| Monthly | Check gas connections, inspect ignition system, clean pilot assembly |
| Quarterly | Inspect thermocouple, calibrate thermostat (if needed), check wiring |
| Annually | Professional inspection of burner, safety valves, and control board |
Complies with NSF/ANSI 4, UL 197, and CSA C22.2 No. 143. Gas installation must conform with ANSI Z223.1/NFPA 54 (National Fuel Gas Code) and local codes. For support, contact Frymaster Technical Service at 1-800-221-4583 or visit www.frymaster.com. Copyright © by Frymaster, a member of the Middleby Corporation.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition / No flame | Gas supply off, clogged pilot, faulty valve | Check manual gas valve; clean pilot orifice; call for service. |
| Oil not heating | Power off, thermostat setting, high-limit tripped | Check POWER switch; verify temp setting; press RESET button. |
| Uneven cooking | Oil level low, baskets overloaded, faulty thermostat | Fill oil to proper level; reduce load; calibrate thermostat. |
| Filter pump not working | Clogged filter paper, cold oil, pump fault | Replace filter paper; heat oil to 250°F; check pump connections. |
| Basket lift not operating | Motor fault, jammed mechanism, blown fuse | Check for obstructions; reset motor overload; replace fuse. |
| Error code on display | Control board fault | Note code, turn power OFF/ON. If persists, call technical service. |
Reset: Press and hold RESET button for 5 seconds to clear non-critical faults.
Service: 1-800-221-4583; www.frymaster.com