Frymaster RE180CS User Manual

The Frymaster RE180CS is a high-capacity electric fryer designed for commercial foodservice operations. It features a 180-pound shortening capacity, solid-state temperature controls, automatic basket lifts, melt cycle, filtration system, and built-in safety features. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Utilities 7. Operating Procedures 8. Filtration & Cleaning 9. Maintenance Schedule 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Stainless steel fry tank with heating elements, Control Panel with digital display, Automatic basket lift system, Filtration valve and pump, Drain pan, Power cord connection.

FeatureDescription
Fry Tank Capacity180 lbs shortening capacity
Heating ElementsImmersion-type, high-wattage elements
Temperature ControlSolid-state digital thermostat (150°F-375°F)
Basket LiftAutomatic hydraulic lift system
Melt CycleAutomatic solid shortening melt function
Filtration SystemBuilt-in pump and filter for oil cleaning
Safety FeaturesHigh-limit thermostat, emergency stop
Power Requirements208-240V AC, 3-phase, 60Hz
Construction304 stainless steel exterior
DimensionsSee specifications section

Installation

Unpack and inspect for shipping damage. Position in designated location.

  1. Location Requirements: Level floor, adequate ventilation, clearance from combustibles.
  2. Electrical Connection: Connect to dedicated 3-phase power supply per local codes.
  3. Ventilation: Connect to approved exhaust hood system.
  4. Initial Filling: Add solid shortening to appropriate level.

WARNING! Installation must be performed by qualified technician. Ensure proper grounding.

First-Time Setup

Power on unit; follow initial startup procedure.

  1. Melt Cycle: Press MELT button to liquefy solid shortening.
  2. Temperature Setting: Set desired cooking temperature (typically 325°F-350°F).
  3. Basket Lift Test: Test automatic lift function without product.
  4. Filtration Test: Run filtration cycle with clean oil to verify operation.

CAUTION! Wear heat-resistant gloves during initial setup. Keep area clear.