The Frymaster SCFHD460G is a high-efficiency gas fryer designed for commercial foodservice operations. It features a 46 lb shortening capacity, solid-state electronic ignition, automatic basket lifts, melt cycle, built-in filtration system, digital temperature control, and stainless steel construction. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Stainless steel fry pot, Electronic control panel, Basket lift mechanism, Filtration system, Gas burner assembly, Drain valve.
| Feature | Description |
|---|---|
| Frying Capacity | 46 lbs shortening capacity |
| Ignition System | Solid-state electronic pilotless ignition |
| Basket Lift | Automatic electric basket lift system |
| Filtration System | Built-in pump filter system |
| Temperature Control | Digital thermostat with high-limit safety |
| Melt Cycle | Automatic solid shortening melt cycle |
| Construction | Type 304 stainless steel exterior |
| Power Requirements | 120V AC, 60Hz for controls |
| Gas Requirements | Natural gas or LP (conversion kit required) |
| Dimensions | See specifications section |
Unpack and inspect for shipping damage. Position on level, stable surface.
WARNING! Installation must be performed by qualified technician in accordance with local codes. Ensure gas connections are leak-free before operation.
Complete installation before initial startup.
CAUTION! Never operate with insufficient shortening. Allow unit to complete initial heat cycle before frying.
Control Panel: POWER switch, Temperature control, MELT button, FILTER button, Basket LIFT/DOWN buttons, High-limit reset.
Temperature Control: Digital display shows set and actual temperature. Use up/down arrows to adjust.
Melt Function: Automatically melts solid shortening at controlled rate to prevent damage.
Filter System: Built-in pump with filter paper. Activated by FILTER button when oil is below 250°F.
Basket Lift: Electric motor with UP and DOWN controls. Automatic timer available on some models.
Gas: 3/4" NPT gas connection. Electrical: NEMA 5-15P plug. Vent: 10" round vent connection.
Tip: Have gas connections pressure tested by qualified technician before first use.
Daily operation steps for optimal performance.
WARNING! Never leave hot oil unattended. Keep floor area clean and dry to prevent slips.
Regular filtration extends oil life and maintains food quality.
CAUTION! Never filter hot oil above 250°F. Always turn power OFF before cleaning interior.
Daily: Filter oil, clean exterior, check temperature calibration. Weekly: Clean burner ports, inspect ignition system. Monthly: Check gas connections, inspect electrical connections.
Annual Service: Have qualified technician perform complete inspection, including gas valve, thermostat calibration, and safety controls.
NSF/ANSI 4 certified for commercial use. AGA/CGA design certified. Meets ASHRAE 154 ventilation requirements. Manufactured by Frymaster, a member of the Welbilt family. For technical support, contact 1-800-221-4583 or visit www.frymaster.com. Serial number located on rating plate inside door.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No ignition | Gas supply, power, ignition module | Check gas valve; verify power; inspect ignition electrodes. |
| Temperature fluctuation | Thermostat, sensor, shorting | Calibrate thermostat; check sensor connection; ensure proper oil level. |
| Basket lift not working | Motor, switch, obstruction | Check power to motor; test switches; remove any obstructions. |
| Oil not filtering | Pump, motor, clogged lines | Verify pump operation; check for clogs in filter lines. |
| Burner flames yellow | Air adjustment, dirty ports | Adjust air shutter; clean burner ports with wire brush. |
Reset: High-limit thermostat may trip; press reset button on limit control.
Service: 1-800-221-4583; www.frymaster.com